Field Tech Guide
Photo requirements, measurements, diagrams, and checklists for every product. This is the definitive reference for field data collection across all 9 product divisions and 40+ products.
The 10 Golden Rules
- Verify ABSoW matches PSoW. Count every installed unit. Flag discrepancies immediately.
- Photograph EVERY unit. Minimum 2 photos per installed unit. Wide + close-up.
- Include a reference object (tape measure, level, hand) for scale in at least one photo per product type.
- Capture labels and markings. Manufacturer stamps, model numbers, batch/lot IDs.
- Measure spacing. Any product with “FT o.c.” or “IN o.c.” — tape measure between units, photo the tape.
- Shoot wide context first. Before close-ups, get a wide shot showing the overall installation area.
- Drive logs are MANDATORY for piers. Push, helical, and slab piers require drive logs. cert-generator-v3 will not generate without them.
- Clean lens, good lighting. Flash in crawlspaces. No blurry shots. Re-take if you can’t read labels.
- Note deficiencies. Missing hardware, improper installation, structural concerns — document with photos AND written notes.
- Upload same day. Photos and logs within 6 hours. Escalation triggers at T+6hr, T+24hr, T+48hr.
01 Underpinning Systems (UND)
UND-PUSH (Push Pier) — SSI, Drivelog Required
- Unit: Quantity (each), Spacing: FT o.c.
- Min Photos: 2 per pier
- Required Addon: Backfill (ADD-BKFL)
Photos Required:
- Bracket & first section — pier bracket secured to footing with first tube section visible (1 per pier)
- Final depth / completion — full pier assembly at final driven depth (1 per pier)
- Pier spacing (wide shot) — multiple piers with tape measure for spacing (1 per wall run)
- Manufacturer label — stamps, model numbers, batch IDs (if visible)
Drive Log Fields: Pier number, date driven, tubes per pier, total depth (ft), PSI per tube section, final PSI at refusal, extension sleeve (Y/N), rated capacity.
UND-HELI (Helical Pile) — SSI, Drivelog Required
- Unit: Quantity (each), Spacing: FT o.c.
- Min Photos: 2 per pier
- Default Spec: Supportworks HP288, 8”-10”-12” triple helix, 2.875” shaft
UND-SLAB (Slab Pier) — SSI, Drivelog Required
- Unit: Quantity (each)
- Min Photos: 2 per pier
02 Anchor Systems (ANC)
ANC-WALL (Wall Anchor) — SSI
- Unit: Quantity (each), Spacing: FT o.c.
- Measurements: Rod length, depth below grade, height above finished floor
ANC-PLATE (Wall Plate Anchor)
- Unit: Quantity (each)
03 Bracing Systems (BRC)
BRC-BEAM (I-Beam/Carbon Fiber Brace) — SSI
- Unit: Quantity (each), Spacing: FT o.c.
- Measurements: Wall placement, position on wall
04 Support Systems (SUP)
SUP-POST (Adjustable Post/Smart Jack)
- Unit: Quantity (each)
- Measurements: Location, height, footer dimensions
05 Foundation Systems (FND)
- Rebar verified, concrete placed
06 Water Management (WTR)
- Pump tested, discharge confirmed
- Sump pump, interior/exterior drain, discharge line
07 Encapsulation Systems (ENC)
- Coverage confirmed, dehumidifier capacity
- Liner thickness, seam sealing
08 Retaining Wall Systems (RTW)
- Wall dimensions, drainage, tiebacks
09 Addon Items
Addon items (ADD-BKFL backfill, ADD-LNRS liner sections, etc.) attach to parent products and are documented as part of the parent’s photo and measurement checklist.
Badge Legend
| Badge | Meaning |
|---|---|
| SSI | Site Submission Item — requires field data |
| DRIVELOG | Drive log required for certification |
| ADDON | Addon / included item |
| PARENT | Parent system with addons |